Myocardial Blood Flow for Ammonia PET Scans

<< Click to Display Table of Contents >>

Navigation:  PXMOD Model Reference > Models with Blood Data >

Myocardial Blood Flow for Ammonia PET Scans

The MBF NH3 (BFM) model implements the pixelwise fitting of a cardiac model for dynamic ammonia PET scans. The model was derived from the parametric mapping method developed by Harms et al [1] for water scans.

The operational equation for cardiac PET includes two geometric spillover fractions (Vlv, Vrv) from left ventricular and right ventricular blood (Clv, Crv):

picture_5877

The tracer concentration in myocardium Cmyo(t) is modeled by a one-tissue compartment model and can be obtained by the convolution of the metabolite-corrected input curve with a decaying exponential, multiplied by K1:

picture_5878

For the ammonia tracer K1 corresponds to mycocardial blood flow (MBF), and k2 to the tissue washout. The linear metabolite correction with slope -mCorr which is applied in this equation was derived by de Grado et al [2] and is only valid for scan durations up to 4 minutes.

The solution of the operational equation uses basis functions of the form

picture_5879

With the basis functions, the operational equation can be reformulated as a multi-linear equation

picture_5880

with

picture_5881

The data analysis methodology then consists of the following two steps:

1.As a preprocessing step the basis functions are calculated for a set of k2 values which span the physiologic relevant range.

2.In each pixel the TAC is fitted by solving the operational equation for all basis functions and selecting the solution which best fits the measurement. From the resulting parameters θ1, Vlv, and Vrv the MBF  (=K1) can readily be calculated.

3.If the blood contribution in a pixel is too high (Vlv+Vrv>0.75), the MBF result is discarded.

Note: The same model is also applied for the MBF parametric mapping ina the cardiac PET tool PCARDP

Data Requirements

Image Data

A cardiac PET data set using the ammonia tracer and acquired for 4 minutes. If the acquisition was longer, only the first 4 minutes should be loaded.

Blood Data

The TAC of blood in the left ventricle and right ventricles is required. Both TACs are applied for a geometrical spillover correction. The LV TAC is also metabolite-corrected and used as the input curve for the 1-tissue compartment model of ammonia.

Data Loading

It is recommended to reorient the images into short-axis (SA) orientation for the processing. This operation can be performed outside of PXMOD. An alternative is to try the PET Heart Reorientation during data loading by the configuration illustrated below. Essentially, the early and the late phases are averaged and an automatic procedure tries finding the SA orientation. For details please refer to the guide of the cardiac PET tool PCARDP which explains the background in more detail.

picture_5882

The example below illustrates a successful reorientation result. If it fails, it is recommended to try optimizing the frame ranges used for averaging.

picture_5883

Masking

It is recommended generating a mask which restricts parametric mapping to the myocardium. This can easily be achieved by a threshold segmentation of the averaged late frames.  

picture_5884

TACs

In SA orientation the definition of VOIs should be relatively easy. In the example below a regular sphere was placed in the LV, scaled and slightly rotated. The RV VOI was created using the paintbrush, and the Myocardial VOI using the >3D region growing.

picture_5885

In order to be independent of the image orientation it is recommended to save the actual curves rather than the VOI definition by the picture_5886 button ton the TACs panel.

Blood Preprocessing

By the saving of the TACs from the TACs panel the references to the curves are directly stored to the Blood Preprocessing panel.

picture_5887

Model Preprocessing

During model preprocessing the basis functions are calculated for the prescribed range of k2. The default range is α1[0.01,2]min-1. Using these basis functions, the myocardial TAC is then fitted.

picture_5888

k2

Define the k2 Range covered by the basis functions by entering the From and To boundaries.

mCorr

Slope of the linear metabolite correction which is applicable for 4 minutes.

#Basis Functions

Number of intermediate k2 values generated in the specified k2 range. The increments are logarithmically spaced.

Resampling

Sampling increment applied during the basis function calculation.

Max. Blood Fraction

The MBF is masked if the calculated blood fraction exceeds the specified value.

Percent masked pixels

Exclude the specified percentage of pixels based on histogram analysis of integrated signal energy. Not applied in the presence of a defined mask.

Model Configuration

The example below shows the default configuration.

picture_5889

MBF

Myocardial blood flow, equal to K1 in the 1-tissue compartment model.

k2

The k2 value which basis function provided the best fit of the data.

vLV

Fraction of blood spillover from the left ventricle.

vRV

Fraction of blood spillover from the right ventricle.

Example

The example below shows the parametric map of the rest scan with a normal volunteer.

picture_5890

References

1.Harms HJ, Knaapen P, de Haan S, Halbmeijer R, Lammertsma AA, Lubberink M: Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner. Eur J Nucl Med Mol Imaging 2011, 38(5):930-939.

2.DeGrado TR, Hanson MW, Turkington TG, Delong DM, Brezinski DA, Vallee JP, Hedlund LW, Zhang J, Cobb F, Sullivan MJ et al: Estimation of myocardial blood flow for longitudinal studies with 13N-labeled ammonia and positron emission tomography. J Nucl Cardiol 1996, 3(6 Pt 1):494-507.