<< Click to Display Table of Contents >> Navigation: PXMOD Model Reference > List of Implemented Models |
The following lists provides a quick overview of the implemented models. If one of the models does not appear in the Model list of the Menu it may have been hidden and can be added using the configuration facility.
Note that outdated models from previous versions have a "Legacy" in the name. These models are only supported for backward compatibility.
Models with Blood Data
Model Name |
Data |
Dynamic? |
Blood? |
Tracers without irreversible uptake. |
yes |
yes |
|
Tracers without irreversible uptake. |
yes |
yes |
|
Tracers without irreversible uptake |
yes |
yes |
|
Tracers which allow time-weighted integral solution. |
yes |
yes |
|
Tracers with 1-tissue compartment kinetics |
yes |
yes |
|
Tracer with 2-tissue compartment kinetics; preferably with K1/k2 constant and k4=0. |
yes |
yes |
|
Tracer with 2-tissue compartment kinetics. Fit with Ridge-Regression |
yes |
yes |
|
Tracer with 2-tissue compartment kinetics, particularly suited for FDG. Basis function fit |
yes |
yes |
|
Tracer with irreversible trapping. |
yes |
yes |
|
Dynamic NH3 PET of the heart. Acquisition duration 4 minutes. |
yes |
no |
|
PET data set using a tracer with irreversible trapping |
yes |
yes |
Receptor Reference Models
Model Name |
Data |
Dynamic? |
Blood? |
Reversible receptor tracers |
yes |
no |
|
123I IBF, 11C Raclopride |
yes |
no |
|
11C DASB |
yes |
no |
|
11C DASB |
yes |
no |
|
11C Raclopride, 11C dMP |
yes |
no |
|
11C Raclopride, 11C CH 23390, 11C CTF |
yes |
no |
|
11C Raclopride, 11C Flumazenil, 18F FCWAY |
yes |
no |
|
FDOPA or another irreversibly binding tracer with a suitable non-trapping reference |
yes |
no |
|
PET data set with a baseline part and an activation part |
yes |
no |
|
11C-MP4A, acetylcholine analog |
yes |
no |
Brain Glucose Consumption
Model Name |
Data |
Dynamic? |
Blood? |
18FDG-PET |
yes |
yes |
|
18FDG-PET |
yes |
yes |
|
14C labeled glucose, autoradiographic cuts |
no |
yes |
|
14C labeled glucose, autoradiographic cuts |
no |
yes |
Models for Dynamic FDG Whole-body Scans
Model Name |
Data |
Dynamic? |
Blood? |
18FDG-PET acquired with non-stationary scanner field-of-view |
yes |
yes |
|
18FDG-PET acquired with non-stationary scanner field-of-view |
yes |
yes |
Brain Perfusion and Blood Volume
Model Name |
Data |
Dynamic? |
Blood? |
H215O-PET |
yes |
yes |
|
H215O-PET |
yes |
no |
|
H215O-PET |
no |
yes |
|
11CO-PET |
no |
yes |
Models for MR Data
Model Name |
Data |
Dynamic? |
Blood? |
DTI/DWI MRI data |
yes |
no |
|
DWI MRI data without diffusion tensor information |
yes |
no |
|
Control, label and proton density images as three separate series |
yes |
no |
|
Resting state MRI data |
yes |
no |
|
MR data acquired using a 4D flow acquisition |
yes |
no |
|
MR data acquired using a 4D flow non-symmetric four-point acquisition |
yes |
no |
Miscellaneous Models
Model Name |
Data |
Dynamic? |
Blood? |
Any dynamic Volume Data |
yes |
no |
|
Any dynamic Volume Data |
yes |
no |
|
Any dynamic Volume Data |
yes |
no |
|
Any dynamic Volume Data |
yes |
no |